ELICA Leaf User's Guide Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
Grease filter signal
After 40 hours of operation LED 1 flashes.
When such signal appears the grease filter installed needs to
be washed.
To reset the signal, keep T4 button pressed for 5”.
The hood gives out a "BEEP" and LED 1 stops flashing.
Charcoal filter signal
After 160 hours of operation LED 2 flashes.
When such signal appears the charcoal filter installed must be
replaced.
To reset the signal, keep T4 button pressed for 5”.
The hood gives out a "BEEP" and LED 2 stops flashing.
In case of contemporaneous signalling of both filters, LEDs 1
and 2 flash alternatively.
To reset, carry out the procedure described above for 2 times.
The first time it resets the charcoal filter signal, the second
time it resets the grease filter signal.
The charcoal filter signal is not active in the standard mode.
In case the hood is used in filter version it is necessary to
enable the charcoal filter signal.
Activating charcoal filter signal:
Set the hood to OFF and press T4 button for 5”.
Once the button has been pressed, the LEDs related to the
filter signals currently active light up.
The hood gives out a "BEEP" and LED 2 flashes for 2".
LEDs 1 and 2 remain on for about 2" before the hood goes
back to OFF.
Deactivating charcoal filter signal:
Set the hood to OFF and press T4 button for 5”.
Once the button has been pressed, the LEDs related to the
filter signals currently active light up.
The hood gives out a "BEEP" and LED 2 switches off.
LED 1 remain on for about 2" before the hood goes back to
OFF.
Maintenance
ATTENTION! Before performing any maintenance operation,
isolate the hood from the electrical supply by switching off at
the connector and removing the connector fuse.
Or if the appliance has been connected through a plug and
socket, then the plug must be removed from the socket.
Cleaning
The cooker hood should be cleaned regularly (at least with the
same frequency with which you carry out maintenance of the
fat filters) internally and externally. Clean using the cloth
dampened with neutral liquid detergent. Do not use abrasive
products. DO NOT USE ALCOHOL!
WARNING: Failure to carry out the basic cleaning
recommendations of the cooker hood and replacement of the
filters may cause fire risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any damage to
the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.
Steam screen
The steam screen must always be left closed and opened only
for maintenance (e.g. cleaning or changing filters).
Grease filter
Fig. 12-25
Traps cooking grease particles.
This must be cleaned once a month (or when the filter
saturation indication system – if envisaged on the model in
possession – indicates this necessity) using non aggressive
detergents, either by hand or in the dishwasher, which must
be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
Open the steam screen.
To remove the grease filter, pull the spring release handle.
Charcoal filter (filter version only)
Fig. 24
It absorbs unpleasant odours caused by cooking.
The charcoal filter can be washed once every two months
using hot water and a suitable detergent, or in a dishwasher at
65°C (if the dishwasher is used, select the full cycle function
and leave dishes out).
Eliminate excess water without damaging the filter, then put it
in the oven for 10 minutes at 100° C to dry completely.
Replace the mattress every 3 years and when the cloth is
damaged.
Montage
Open the steam screen and remove the grease filter.
Install the carbon filter on the back of the grease filter and
fix with two rods.
Attention! The rods are included in the carbon filter
packing and not on the hood.
To dismantle the filter act in the reverse manner.
Replacing lamps
Fig. 26
Disconnect the hood from the electricity.
Warning! Prior to touching the light bulbs ensure they are
cooled down.
Remove the top cover for access to the neon bulb
compartment.
Remove the bulb and replace with a new one, use only
neon bulbs type G5-T5 14W max (4000°K).
If the lights do not work, make sure that the lamps are fitted
properly into their housings before you call for technical
assistance.